# How to read a certificate of analysis (COA)

Updated 2026-10-17.

A certificate of analysis (COA) is a dated, signed list of test results for one production run, or batch. ICH Q7 is the good-manufacturing-practice guide for active pharmaceutical ingredients (version dated 10 November 2000). It comes from the International Council for Harmonisation. Clauses 11.40 to 11.43 say an authentic COA should be issued for each batch on request. It should list each test, its acceptance limits and its numerical results. Reading a COA starts with one match. The lot number on the label must match the lot number on the COA.

| | |
| --- | --- |
| Document type | The test record for one batch. An authentic certificate should be issued for each batch on request ([ICH Q7](https://database.ich.org/sites/default/files/Q7%20Guideline.pdf), 10 November 2000 version, clause 11.40, read 14 October 2026) |
| Issued by | Dated and signed by authorised staff of the quality unit. It shows the original manufacturer's name, address and telephone number (ICH Q7, clause 11.43) |
| Lot number | The batch number is among the details the certificate should carry (ICH Q7, clause 11.41). It is the string that ties a physical label to this document |
| Lists | Each test performed, its acceptance limits and the results, if results are numbers (ICH Q7, clause 11.42) |
| Identity line | Whether the molecule is the one the label names |
| Purity line | How much of the measured signal is that molecule, usually as an HPLC area percentage |
| Does not show | Safety, regulatory approval, or fitness for any human use. ICH Q7 does not describe the certificate as an approval of the material |
| Contents guideline | ICH Q7, 10 November 2000 version, clauses 11.40 to 11.44. It asks for a certificate for each batch on request. It asks for each test, limit and numerical result, and a signature. It also sets rules for re-issued certificates |
| Raw-material reliance | At least one identity test per batch of incoming material. A supplier's COA can replace other tests where the maker has a system to evaluate suppliers (ICH Q7, clause 7.30) |
| Safety data sheet (SDS) | A separate document about hazardous chemicals. It has 16 numbered sections (Safe Work Australia, [Code of Practice](https://www.safeworkaustralia.gov.au/doc/model-code-practice-preparation-safety-data-sheets-hazardous-chemicals), updated 16 June 2023) |
| Turnaround | No fixed time appears in ICH Q7 section 11.4 or in 21 CFR 211.84(d). The eCFR text was read 14 October 2026 |
| Sources checked | 14 October 2026 |

A small vial arrives with a sheet of paper. Before any number on that sheet means anything, one string of characters has to match. That string is the lot number, the code for one production run, also called a batch. The lot number on the label must be the same as the one at the top of the certificate. Until the two agree, the document does not show that it covers this container.

This page is part of [the peptide quality & verification hub](/learn/peptide-quality-verification). It walks through that sheet line by line. It shows what each field records, what a purity percentage shows, and where the paperwork stops. Purity usually arrives as an HPLC area percentage. HPLC (high-performance liquid chromatography) is a method that separates a mixture so each part shows as its own peak. Two questions run through the whole page. The first is identity: is the molecule the one named on the label? The second is purity: how much of the measured signal is that molecule?

## What is a certificate of analysis?

A certificate of analysis is the dated, signed test record for a single batch. It lists each test performed with its acceptance limits and the numerical results. The International Council for Harmonisation describes this record in [ICH Q7](https://database.ich.org/sites/default/files/Q7%20Guideline.pdf). ICH Q7 is its good-manufacturing-practice guide for active pharmaceutical ingredients (10 November 2000 version, read 14 October 2026). Clause 11.40 says authentic COAs should be issued on request for each batch. Clauses 11.41 to 11.43 set out what they carry. The COA relates to a particular batch. It does not relate to the product line as a whole. That is why the sheet travels with the material it describes.

The guide's wording is per batch, because a test result only describes the material actually tested. A product line can run for years. A batch is one bounded run. Only the sheet carrying its number speaks for it. Published papers describe a compound across trials. [The retatrutide research guide](/research/retatrutide) collects such papers. A certificate speaks for a single production run.

## What should a certificate of analysis include?

ICH Q7 says the certificate should give the name of the intermediate or active pharmaceutical ingredient. It should give its grade where it applies, the batch number and the date of release. It should add an expiry or retest date where one applies (clause 11.41). It should list each test with its acceptance limits and the results, if results are numbers (clause 11.42). It should be dated and signed by approved quality-unit staff. It should show the name, address and telephone number of the original manufacturer (clause 11.43). Where a repacker or reprocessor did the analysis, theirs should be shown as well.

The manufacturer line is where origin enters the picture. The sheet names who made the material. Where a repacker or reprocessor did the analysis, it also names who handled the material later (ICH Q7, clause 11.43). The story of [where tirzepatide comes from](/learn/retatrutide/where-does-tirzepatide-come-from) covers sourcing of a related peptide.

Clause 11.42 asks for the acceptance limit and, for numerical tests, the numerical result. A result printed next to its limit gives a reader more to check than a bare word.

## Does a COA prove identity or purity?

Identity and purity are two different tests. A certificate lists each one separately. Identity asks if the molecule is the one named on the label. Purity asks how much of the measured signal is that molecule. [ICH Q6A](https://database.ich.org/sites/default/files/Q6A_Guideline.pdf) is the ICH guide to specifications for new drug substances and products (6 October 1999 version, read 14 October 2026). It says one retention time alone is not specific for identity. A retention time is how long a sample takes to leave a test column. Two procedures built on different principles are generally acceptable. So is a combined test such as HPLC/MS (section 3.2.1). MS (mass spectrometry) weighs a molecule and its fragments.

A 2023 report from the United States Pharmacopeial Convention (USP) covers peptide reference standards. It uses case studies of six peptides. It is not a survey of commercial lots. It lists four identity tests. NMR shows structural features. LC–MS/MS gives peptide mass and amino acid sequence. HPLC compares a sample with a standard. Amino acid analysis tells leucine from isoleucine (McCarthy et al., *Pharmaceutical Research*, 2023). Q6A is written for drug specifications. It is not written for research catalogues. [The retatrutide molecular-formula record](/learn/retatrutide/retatrutide-molecular-formula) is the registry-level counterpart. It ties a sequence to a checkable mass.

## Can a certificate of analysis be wrong?

A laboratory audit looked at 98 synthetic quorum-sensing research peptides. The linear ones came from one international supplier. The cyclic ones came from another. The audit asked for a minimum purity of 95.0%. All 98 came with a COA stating at least 95.0% purity. Yet in-house testing found that only 43 of the 98 met that purity. This finding is for that peptide class and those two suppliers only (Verbeke et al., *Journal of Pharmaceutical Analysis*, 2015). So the gap between paperwork and measurement is documented for that sample. It is not shown for every catalogue. A percentage on a sheet is a claim about a run, and claims can miss.

The method changes the number. In the Verbeke et al. audit of 98 quorum-sensing peptides from two suppliers, one peptide was claimed at 95.0% purity or more. The supplier used its own chromatography system. The peptide measured 80.6% in the researchers' laboratory. That result is for that single specimen only (Verbeke et al., *Journal of Pharmaceutical Analysis*, 2015). The audit also looked at nine cyclic quorum-sensing peptides from one supplier. None measured above 90.0% in-house, although each came with a certificate stating at least 95.0%. That result does not extend to current catalogue lots (Verbeke et al., 2015). A percentage without its method is hard to compare across systems. The method includes the column, solvents, gradient and wavelength. The sheet states a result. The method states what the result means.

## Is purity the same as peptide content?

A headline purity percentage is not the peptide content by weight. A 2023 USP report covers peptide reference standards. It describes a mass-balance approach. That approach gives a bulk peptide a quantity value. The tests include purity by chromatography. They include acetic acid and trifluoroacetic acid content, residual solvents and residue on ignition (McCarthy et al., *Pharmaceutical Research*, 2023). The report uses case studies of six peptides. It is not a survey of commercial lots. Share of signal and share of mass answer different questions. Identity, purity and content are three separate questions.

The purity line on a sheet answers one of the three: purity, the share of signal. In the McCarthy report, content (strength) and identity each have their own tests beside the purity test. They are listed in the report's Table II. A reader who keeps the three questions apart will read every certificate more accurately. A reader who lets one percentage stand for all three will not.

## What is the purpose of a certificate of analysis?

A certificate of analysis lets a receiving party see which tests a batch passed without repeating every one of them. [ICH Q7](https://database.ich.org/sites/default/files/Q7%20Guideline.pdf) says the receiver should run at least one test to verify the identity of each batch of incoming material. There are exceptions in clause 7.32. It also says a supplier's COA can be used in place of other tests (clause 7.30). The maker must have a system in place to evaluate suppliers. The US rule for drug components is [21 CFR 211.84(d)(2)](https://www.ecfr.gov/current/title-21/chapter-I/subchapter-C/part-211/subpart-E/section-211.84) (eCFR text read 14 October 2026). It allows a report of analysis from the supplier in two cases. The maker must run at least one specific identity test. The maker must also show that the supplier's analyses are reliable. It does this through validation at set intervals. So a COA is a basis for trust, with checks attached.

The checks come on a schedule. ICH Q7 says a full analysis should be done at set intervals. It should be compared with the COAs. It says the 'Reliability of Certificates of Analysis should be checked at regular intervals' (clause 7.31). In plain terms, the paper is accepted and then audited. The 98-peptide re-testing audit above is the same idea. A research laboratory ran it for one peptide class from two suppliers. It checked COAs against measurement (Verbeke et al., *Journal of Pharmaceutical Analysis*, 2015).

## What does a certificate of analysis look like?

ICH Q7 lists what the document carries. That is the product name and grade, the batch number, the release date and any expiry or retest date. It is each test with its acceptance limit and result. It is also the date, signature and manufacturer details (clauses 11.41 to 11.43). A reader can sort these into three working zones. They are a header that names the product and batch, a results table, and a signed footer. That grouping is this page's own, not a layout the guideline sets. No guideline opened for this page fixes a page design. So layouts differ between laboratories and suppliers.

The header holds identity: product, grade, lot, release date. The table holds evidence: one row per test, with a limit beside each result. The footer holds accountability: a date, a signature from quality-unit staff, and the maker's name, address and telephone number. The comparison table below sketches the same layout field by field.

One variation matters for supply chains. A repacker, agent or broker may issue a new certificate. ICH Q7 says it should show the name, address and telephone number of the laboratory that did the analysis. It should refer to the original manufacturer. It should carry the original batch certificate, 'a copy of which should be attached' (clause 11.44). A re-typed sheet with no such reference has no clear link back to the lab that measured anything.

## How is a certificate of analysis read, step by step?

A certificate of analysis can be read in this order. Read the lot number first. Then read the dates. Then read each result against its limit. Then read the signature and issuer. The order is this page's suggestion, not one set by a guideline. The lot number comes first because every figure describes only the batch the sheet names (ICH Q7, clauses 11.40 and 11.41). Dates come next. ICH Q7 asks for a release date and, where one applies, an expiry or retest date. The results table then pairs each test with its acceptance limit and its result (clause 11.42). The issuer line closes the check. Clause 11.43 asks for a signature from approved quality-unit staff.

The method belongs in the reading too. A percentage with no stated method is hard to compare. In the Verbeke et al. audit of 98 quorum-sensing peptides from two suppliers, one peptide was claimed at 95.0% purity or more by its supplier's system. It measured 80.6% by the researchers' own. That result is for that single specimen only (Verbeke et al., *Journal of Pharmaceutical Analysis*, 2015). The method line is the part of the sheet that says what the number means.

The order is a habit, not a ritual. [How to check that a peptide certificate is genuine](/learn/peptide-quality-verification/how-to-check-a-peptide-coa-is-genuine) takes the same sheet through the checks that sit outside the page itself.

## What is a certificate of analysis for raw materials?

A certificate of analysis for a raw material is the supplier's test record for one lot. The lot is an incoming starting material, reagent or solvent. ICH Q7 defines a raw material as 'a general term used to denote starting materials, reagents, and solvents intended for use in the production of intermediates or APIs' (glossary). The maker who receives it runs at least one identity test per batch. The supplier's COA can replace other tests. The maker needs a system to check suppliers (clause 7.30). Some raw materials need not be tested if the maker's COA is obtained. These are processing aids and hazardous or highly toxic raw materials. The lack of on-site testing should be justified and written down (clause 7.32).

In plain terms, the buyer of a raw material tests a little. It relies on the COA for the rest and writes down why. The COA on a finished peptide is a separate document about a different lot.

The guideline's reach is limited. ICH Q7 covers making active ingredients for human drug products (section 1.3). So its raw-material rules describe drug-industry practice. They do not describe research catalogues.

## What is a certificate of analysis in the pharmaceutical industry?

In the drug industry, a certificate of analysis is a document for one batch. The maker's quality unit issues it. It lists the tests, limits and results for that batch. ICH Q7 says authentic certificates should be issued on request for each batch. This covers an intermediate or active pharmaceutical ingredient (API). An API is the active substance in a medicine. The certificates should be dated and signed by approved quality-unit staff (clauses 11.40 and 11.43). In the United States, [21 CFR 211.84(d)(2)](https://www.ecfr.gov/current/title-21/chapter-I/subchapter-C/part-211/subpart-E/section-211.84) lets a drug maker accept a supplier's report of analysis for a component. Set conditions apply (eCFR text read 14 October 2026).

Clause 11.40 asks for 'authentic' certificates. Clause 11.44 shows one way that is protected. When a repacker or broker re-issues the sheet, the original batch certificate should be attached.

ICH Q7's scope (section 1.3) covers active ingredients for human drug products. A research-use-only certificate is not within that scope. [What a lot number lets a researcher verify](/learn/peptide-quality-verification/what-a-batch-or-lot-number-lets-a-researcher-verify) explains how far the lot-number chain can be checked on its own.

## Is CMC in an eCTD the same as a batch certificate?

No. A batch certificate reports results for a named batch. CMC is part of a drug file that explains its quality. It stands for chemistry, manufacturing and controls: what is made and how quality is checked. An eCTD is the electronic Common Technical Document, the format for that application. A batch sheet alone is not that full file.

The FDA places this quality information in Module 3 of the application. Its PQ/CMC page was checked 17 October 2026. ICH, the body behind the format, describes five modules in total. They organise quality, safety, and evidence about whether the drug works.

A useful picture is a sheet beside a folder of evidence. The sheet answers a question about one batch and its tests. The folder has a much wider purpose. A batch sheet cannot show that a full file was sent or accepted.

![A batch report sheet sits beside a larger application folder containing quality evidence.](/assets/content/hub-batch-sheet-application.png)

A batch sheet reports one batch. CMC is wider quality information in a drug application. Sources: FDA PQ/CMC and ICH Common Technical Document; checked 17 October 2026.

## What is the difference between a COA and an MSDS?

A certificate of analysis reports test results for one batch. A safety data sheet (SDS) reports hazard and handling facts for a chemical. SDS is the current name for an MSDS. The Safe Work Australia [Code of Practice](https://www.safeworkaustralia.gov.au/doc/model-code-practice-preparation-safety-data-sheets-hazardous-chemicals) was last updated 16 June 2023 and read 14 October 2026. It says an SDS, 'previously called a Material Safety Data Sheet (MSDS)', gives information about hazardous chemicals. This includes the chemical's identity and ingredients. It includes health and physical hazards. It includes handling and storage, emergency steps and disposal (section 1.1). ICH Q7 describes a COA as a record of tests, limits and results for each batch (clauses 11.40 to 11.42). One document reports what was measured in a batch. The other reports what is known about a chemical's hazards.

The Code lists 16 numbered sections for an SDS. They run from section 1, identification, to section 16, 'Any other relevant information'. They include section 7, 'Handling and storage'. They include section 11, 'Toxicological information'. A COA has no such sections. Work health and safety regulation 330 is set out in the Code. Under it, a maker or importer of a hazardous chemical must prepare an SDS for it.

Neither document shows that a chemical is safe for human use. Whether a given research material counts as a hazardous chemical is a classification question. This page does not decide it. A supplier may hold both documents for one product. Each one answers a different question.

## How is a certificate of analysis obtained?

A certificate of analysis comes from the party that tested the batch. ICH Q7 says authentic certificates should be issued for each batch 'on request' (clause 11.40). This site's [shipping page](/shipping) says Certificates of Analysis are available on request. Its home page labels the certificate it displays as a historical GHK-Cu sample report, not a current catalog lot certificate (both read 14 October 2026). A COA describes one lot. So a request is tied to a lot number. A sample report or a sheet for another lot does not describe the batch in hand.

A reseller or broker may supply the sheet instead. Then the clause 11.44 test applies. The sheet should show the laboratory that performed the analysis. It should refer to the original manufacturer and attach the original batch certificate. A sheet that cannot be traced to a laboratory is a claim, not a record.

## What has research not shown about certificates of analysis?

The sources read for this page did not show that a certificate of analysis proves safety. They did not show it proves regulatory approval or suitability for human use. A COA records one batch's tests and nothing beyond them. The one re-testing study in the sources covers 98 quorum-sensing peptides from two suppliers. It was published in 2015. It does not cover any 2026 catalogue (Verbeke et al., *Journal of Pharmaceutical Analysis*, 2015). ICH Q7 and ICH Q6A are guideline expectations for drug making. They are not studies. Their stated scope is drug products, not research-use-only catalogues.

The USP report describes how peptide reference standards are characterised. It uses case studies of six peptides, not commercial lots. Its mass-balance material is an example. It is not a measurement of any product (McCarthy et al., *Pharmaceutical Research*, 2023). Research-use-only material is not a medicine, is not a substitute for any medicine, and is not for human or animal use. The sheet records tests on a batch. It shows nothing beyond the tests.

## Comparison

Field by field: what each line of a batch certificate can establish, and what it cannot. This is a generic sketch, not a real or supplier certificate.

| COA field | What it can show | What it cannot show |
| --- | --- | --- |
| Product name + batch/lot number | Which production run this sheet describes (ICH Q7, clause 11.41) | That the container in hand came from that run (label must match) |
| Release date + expiry/retest date | The date of release and, where one applies, the expiry or retest date (ICH Q7, clause 11.41) | What happened to the material after release |
| Identity test line (e.g. HPLC + MS) | Whether the molecule matches the named one. ICH Q6A accepts two procedures on different principles, or HPLC/MS | Identity from a single retention time alone (ICH Q6A, section 3.2.1) |
| Purity line (HPLC area %) | How much of the signal was the target molecule, by that method | Peptide content by weight, or results by a different method |
| Results table (test, limit, result) | Each test performed, its acceptance limit and its numerical result (ICH Q7, clause 11.42) | What the number means without its method, or whether the method suits the molecule |
| Signature, date, manufacturer details | Who signed for the quality unit and who made the batch (ICH Q7, clause 11.43) | Anything about safety or approval |
| Reference to the original certificate (repacked or re-issued sheets) | Which laboratory performed the analysis and which maker produced the batch (ICH Q7, clause 11.44) | The chain to the original test record, when no original certificate is attached |

## Frequently asked questions

### What does COA stand for?

COA stands for certificate of analysis: the batch's test record, issued per lot with tests, limits, and results (ICH Q7, clauses 11.40 to 11.42). The letters name a document tied to one production run, not a product line. Without a matching lot number, the document does not show that it covers this container.

### What does 95% purity mean on a certificate of analysis?

A 95% purity line is usually an HPLC area percentage. It means about 95% of the measured signal was the target molecule, by that method, in that run. A supplier claim can still miss. A laboratory audit looked at 98 quorum-sensing research peptides from two suppliers. All 98 came with COAs stating at least 95.0% purity. Yet in-house re-testing found only 43 met that purity. This finding is for that peptide class only (Verbeke et al., *Journal of Pharmaceutical Analysis*, 2015).

### How do I verify a certificate of analysis?

ICH Q7 lists what a batch certificate carries. That is the batch number, the release date and any expiry or retest date. It is each test with its limit and numerical result. It is also a signature with the manufacturer's details (clauses 11.41 to 11.43). Matching those fields to the label of a container is a document check. It does not test the material itself. Each step is small. Together the steps tie one container to one record.

### Is a certificate of analysis enough to prove a product is genuine?

A certificate of analysis is the maker's own batch record, not independent proof. A laboratory audit looked at 98 quorum-sensing research peptides from two suppliers. In that audit, 55 of the 98 did not meet the 95.0% purity stated on their COAs. This finding is for that peptide class only (Verbeke et al., *Journal of Pharmaceutical Analysis*, 2015). The sheet is evidence from the maker. Evidence from the maker has limits.

### What is a CoA certificate?

A CoA certificate is a certificate of analysis. It is the dated, signed record of the tests, limits and results for one batch (ICH Q7, clauses 11.40 to 11.43). ICH Q7 does not describe the document as an approval of the material.

### How long does it take to get a certificate of analysis?

No source opened for this page sets a turnaround. ICH Q7 says only that authentic certificates should be issued for each batch on request (clause 11.40). The time depends on the tests listed. Some tests run for fixed periods. A 2018 lab comparison of sterility tests says the standard sterility test needs a 14-day incubation. That is about that test. It is not about any certificate request (Bugno et al., *Journal of Pharmaceutical Innovation*, 2018). This site's shipping page says only that Certificates of Analysis are available on request (read 14 October 2026).

## Citations

- Verbeke F et al.. Journal of Pharmaceutical Analysis. 2015;5(3):169-181. DOI: 10.1016/j.jpha.2014.12.002
- McCarthy D et al.. Pharmaceutical Research. 2023;40(6):1317-1328. DOI: 10.1007/s11095-023-03493-1
- Bugno A et al.. Journal of Pharmaceutical Innovation. 2018;13(1):27-35. DOI: 10.1007/s12247-017-9303-z
- U.S. Food and Drug Administration. Pharmaceutical Quality - Chemistry, Manufacturing & Controls. PQ/CMC overview and Module 3; checked 17 October 2026. DOI: https://www.fda.gov/industry/fda-data-standards-advisory-board/pharmaceutical-quality-chemistry-manufacturing-controls-pqcmc
- International Council for Harmonisation. M4: The Common Technical Document. Application modules and electronic format; checked 17 October 2026. DOI: https://admin.ich.org/page/ctd
- International Council for Harmonisation. ICH Q6A. Specifications for new drug substances and products, 6 October 1999. DOI: https://database.ich.org/sites/default/files/Q6A_Guideline.pdf
- U.S. Code of Federal Regulations. 21 CFR 211.84. Testing and approval or rejection of components, containers, and closures. DOI: https://www.ecfr.gov/current/title-21/chapter-I/subchapter-C/part-211/subpart-E/section-211.84
- Safe Work Australia. Model Code of Practice. Preparation of safety data sheets for hazardous chemicals. DOI: https://www.safeworkaustralia.gov.au/doc/model-code-practice-preparation-safety-data-sheets-hazardous-chemicals

[Retatrutide reference material](/shop/retatrutide)

[More on peptide quality & verification](/learn/peptide-quality-verification)

---

Canonical page: https://www.formlaboratories.com/learn/peptide-quality-verification/how-to-read-a-certificate-of-analysis

Form Laboratories - Perth-based research-use-only peptide supplier, shipping Australia-wide.

- Site guide for agents: https://www.formlaboratories.com/llms.txt
- Sitemap: https://www.formlaboratories.com/sitemap.xml
- Full catalogue: https://www.formlaboratories.com/shop
- Contact: hello@formlaboratories.com

All materials are supplied for laboratory research use only - not for human or veterinary use, and nothing on this site is medical advice.